You bring the survey report for your plot and your brief. We read the plot, build one model from it, and produce every discipline’s drawings and quantities from that same model. Each stage is reviewed before the next begins.
Plot 542MadabaReport 1/2024
Real data
From the plot
01
Receive the plan.
You send the boundary survey report for your plot from the Land and Survey Department, with your brief: rooms, area and style. The report gives every boundary point as a coordinate.
Report 1/2024Points 7Arc sides 1
02
Read and verify.
We draw the plot from its coordinates, compute every side, the arc and the area, and check them against the report. A figure that does not match is a finding, and it is raised before anything is built on it.
Plot area, recomputed1,356.40m²The report states 1,356.40 m². Difference 0.00 m².
Frontage, side 3–438.64mOn a 12 m earth road.
Apply the zoning, once it is confirmed.
Setbacks, floors and coverage come from your municipality’s zoning for the plot, never from a habit. Until they are confirmed, the setback is drawn as an assumption and labelled as one.
Buildable zone720.99m²With a 4.00 m setback on every side: an assumption to confirm.
Model SampleLevels 03LOD 350
Not issued
To one model
03
The model, before any drawing.
Plans and a 3D model with finishes, which you review and adjust before a single construction drawing is made. Drawings are a rumour; the model is the truth.
04
Structure, in the same model.
Columns, beams and slabs are modelled on the same grid, at the same levels. Foundations are not finalised without a soil investigation report.
05
Complete MEP, not a sketch of it.
Electrical, mechanical and plumbing are modelled complete, in the same coordinates. As each system arrives, every crossing with the structure is found and counted.
06
Coordination: count, resolve, list what is open.
Every clash has an ID, an overlap in millimetres and a state. Resolved rows stay in the list. What is still open is named, with its reason, before drawings are issued.
Clashes found14In the sample model on this page.
Open1CL-0417, duct through transfer beam.
07
Signed, then handed over.
Every drawing and model is reviewed and signed by an engineer registered with the Jordan Engineers Association before it is delivered. You receive DXF and DWG drawings, PDFs, the model and a walkthrough video, organised with clear layers and naming.
Handover recordLive
open clashes 14 → 0 · 14 / 14 resolved
Disciplines
Six disciplines, one set of coordinates.
Every discipline starts from the same model, so a change in one is seen in all of them. That is where fewer clashes come from.
01Architecture and interior designPlans, elevations, sections, finishes
02Structural engineeringGrid, members, slabs, foundations after the soil report
03ElectricalPower, lighting, trays and risers
04Mechanical and plumbingDucts, pipes, wet services
05Bills of quantitiesCounted from the model, element by element
063D views and walkthrough videoTaken from the model you approved
Start with your plot.
Send us the survey report for your plot and your brief. We return the plot read and checked, and the first model to review.